Si5040
60 Rev. 1.3
Reset settings = 0010 1001
Reset settings = 0000 1111
Register 26. RxSqmConfig
BitD7D6D5D4D3D2D1D0
Name RxSqmThresh[5:0]
Type R/W R/W R/W
Bit Name Function
7:2 RxSqmThresh[5:0] Receiver Signal Quality Monitor Threshold.
Threshold used to assert SQM LOS alarm.
00 0000 = 0 (decimal)
11 1111 = 63 (decimal)
Note: Default = 10 (decimal)
1 Reserved Do not change; must only write 0 to this bit.
0 Reserved Do not change; must only write 1 to this bit.
Register 27. RxSqmDeassertThresh
BitD7D6D5D4D3D2D1D0
Name RxSqmDeassertThresh[5:0]
Type RR/W
Bit Name Function
7:6 Reserved Read returns zero.
5:0 RxSqmDeassertThresh[5:0] Receiver Signal Quality Monitor Deassert Threshold.
Value where the SQM alarm is removed.
00 0000 = 0 (decimal)
11 1111 = 63 (decimal)
Note: Default = 15 (decimal)