Datacom Systems Inc
VERSAstream
™
1000 • USERguide
23
To connect the VERSAstream
™
Multi-Link Aggregator kit, refer to Figure 15 or
Figure 17 and follow these steps:
1. Four power supplies are provided, two power supplies per Multi-Link Aggregator
unit. Use of the second power supply per unit is strongly recommended to assure
uninterrupted monitoring. Connect both power supply barrel connectors into the
power 1 and 2 ports, respectively, of the VERSAstream
™
. Plug the power sup-
plies into the external power source, furthermore, connecting the second power
supply to a different external power source circuit than the first power supply
eliminates power as a single point of failure. The POWER 1 and 2 LEDs illumi-
nate indicating power 1 and 2, respectively, are on. Either LED not illuminated
indicates a defective power source and immediate replacement is required to
insure redundant power integrity.
2. Connect network cables to the VERSAstream
™
NETWORK
RJ45 ports. The
NET-
WORK
RJ45 Link LED is solid green indicating link has been established
between the respective
NETWORK
port and network device. See Table 3 for RJ45
LED display codes. The LED is flashing green when data is passed from the
respective network device to the network port.
3.
Connect analysis devices to the VERSAstream
™
MONITOR
ports. Four DRL494–2m
cables are provided, two per unit, to connect analysis SC ports to the
MONITOR
duplex-LC ports. Either, the
MONITOR
duplex-LC Link LED or the
MONITOR
RJ45
Link LED is solid green when link has been established between the respective moni-
tor port and analysis device. The LED is flashing green when data is passed from the
respective monitor port to the analysis device.
4. Two DRL366-1 cables are provided, connect one DRL366-1 cable from the
DAISY OUT
port of one VERSAstream
™
unit to the
DAISY IN
port of the second
VERSAstream
™
unit. Connect the other DRL366-1 cable from the
DAISY IN
port
of the first unit to the
DAISY OUT
port of the second unit.
1,000 Mbs
100 Mbs
10 Mbs
Green
Orange
OFF
RJ45 LED Display Code
Link
Data
Code
Left LED
Solid Green
Flashing Green
Code
WITH LINK OR DATA
Right LED
Table 3 - RJ45 LED Display Codes